Upgrade Your Tempus LX Network Time Server
Free Software Upgrades
We provide free software upgrades for our products The software available on this page is for the Tempus LX Network Time Server. Here are the latest binary image files:
- Linux Subsystem (Root File System)
- What is the number of your current software? You need to know this number in order to get the correct binary image for upgrading the Linux/NTPÌýSubsystem of your Tempus LX. To get the software number type command: "gntpversion" for Tempus LXÌýGPS or "cntpversion" for Tempus LXÌýCDMA. You will see the software number displayed like this:
- Ìý
- Tempus LX GPS 6010-004x-000ÌýÌýorÌýÌýTempus LX CDMA 6010-004x-000
- Ìý
- Click here if x=2 (software number is 6010-0042-000)
- Click here if x=4 (software number is 6010-0044-000)
- Ìý
- Receiver Subsystem (GPS or CDMA)
- Current revision level is v5.11.
- You may not need to upgrade. Check the history of software changes first.
- If you do decide to upgrade the Receiver Subsystem then be sure to also upgrade the Linux/NTPÌýSubsystem.
- ClickÌýhereÌýto download GPS/CDMAÌýSubsystem 6010-0020-000 v5.11.
Ìý
Upgrade Instructions
For complete instructions, please refer to "Appendix B - Upgrading the Firmware" of your User Manual.Ìý If you want to download the latest manual clickÌýhereÌýfor the Tempus LX (GPS) User Manual andÌýhereÌýfor the Tempus LX (CDMA) User Manual.
If you have any questions or problems with the upgrade please contact customer support byÌýemailÌýor phone: 707-573-8633.
Ìý
History of Software Changes
LinuxÌýSubsystem (Root File System) — Software Part Numbers 6010-0042-000 and 6010-0044-000
Version | Changes |
5.70 | Patches applied to correct Shellshock vulnerabilities.Ìý Please see Field Service BulletinÌýFSB140926-02. RECOMMENDATION: Please upgrade unless you have secured the network port on your Time Server per the instructions in the Bulletin. NOTE 1:Ìý If you are upgrading and the current version in your unit is 5.50 or less, then pleaseÌýread this first. |
5.67 | Minor bugs fixed in the PTP option. RECOMMENDATION: No need to upgrade unless one you have the PTP Option. |
5.64 | 1.ÌýFixed bug where sometimes, at first power-up after being shipped from factory, the NTP daemon would take a longer time than normal to indicate lock status. 2.ÌýFixed bug in HTTP interface where it reports NTP Stratum 16 when the actual Stratum is any level greater than 2. 3.ÌýFixed bug introduced at version 5.60 where the ntp daemon continues to serve Stratum 1 time after receiver subsystem goes unlocked for an extended period. RECOMMENDATION: No need to upgrade unless one of these items is important to you. |
5.63 | Fixed minor bug - erroneous SNMP traps when NTP is flooded with packets. RECOMMENDATION: No need to upgrade unless this is important to you. |
5.62 | 1.ÌýPTPv2 Option: Removed PTP "Port State = Listen" which could prevent the clock from becoming "Port State = Master". 2.ÌýFixed polling fault that may occur when the unit is powered up the very first time only. RECOMMENDATION: Upgrade if one of the above items is important to you. |
5.61 | 1.ÌýPTP Option: Fixed mishandling of packet sequence numbers when packets are dropped. 2.ÌýFixed bug where password is displayed when upgrading firmware using the Web Interface. 3.ÌýFixed bug that prevents you from upgrading firmware using the Web Interface and the "Upgrade From Local File" option.Ìý Because of this flaw in your current version you must upgrade using the Web Interface and the "Upgrade From FTP Server" option, or by using the command line interface. 4.ÌýFixed bug introduced with change to NTP distribution 4.2.6p3 where ntpd would terminate if user did not configure network settings. RECOMMENDATION: Upgrade if you have the PTP Option or use the Web Interface. |
5.60 | 1.ÌýUpdated NTP distribution version to 4.2.6p3 which solves the vulnerability below (item #5) and also improves timing jitter performance. 2.ÌýAdded version 2 for PTP/IEEE-1588.Ìý This only pertains to those who have purchased the PTP Option.Ìý For information on PTP version 2 see Appendix H in the latest User Manual (clickÌýhereÌýfor GPS andÌýhereÌýfor CDMA). 3.ÌýFixed domain name bug for domains with more than one '.' in them. 4.ÌýFixed rare Secure Shell permissions bug. 5.ÌýWorkaround for ntpq/ntpdc remote query vulnerability.Ìý Did this even though the updated NTP distribution should solve the problem. RECOMMENDATION: Upgrade if one of the above items is important to you. |
5.50 | 1.ÌýAdded capability for PTP/IEEE-1588 Option that allows setting of multicast time-to-live (ttl) variable. 2.ÌýAdded capability to edit and view the Domain Name Server (DNS) via the front-panel keypad/display. 3.ÌýFixed a bug related to erroneous SNMP FaultStatus2 traps. 4.ÌýFixed a bug in the "gpsrefpos" command which inhibited showing reference position in "unknown" and "dynamic" modes (GPS model only). 5.ÌýAdded Web Interface (HTTPS) for monitoring status of all functions and for upgrading software.Ìý This new capability is only for units with Software Number 6010-0044-000.Ìý The Web Interface is disabled for units with Software Number 6010-0042-000 (because these are older units and the required hardware is not available). RECOMMENDATION: Upgrade if one of the above items is important to you. |
5.11 | Fixed a bug related to the gntpuser or cntpuser login.Ìý If you are having trouble logging in to your unit then upgrading your software will not correct the problem.Ìý Please see thisÌýField Service Bulletin. RECOMMENDATION: No need to upgrade. |
5.11 | New option added to the product line: Precision Time Protocol (PTP/IEEE-1588). RECOMMENDATION: No need to upgrade. |
5.00 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
4.00 | 1.ÌýAdded capability for CDMA model to operate in India. 2.ÌýModified the start-up sequence to eliminate the need for operator intervention in order to show the time on the display.Ìý Now the unit will go to the time display 30 seconds after the startup sequence has finished. 3.ÌýAdded additional format selections to the Serial Time Output Option. 4.ÌýChanged TFOM value for GPS model to be in the range of 9-3 (was 9-4).Ìý Note: TFOM is usually irrelevant for time server customers. 5.ÌýAdded CRC checking on the time information going from the Receiver Subsystem to the NTP Subsystem.Ìý This will further bulletproof the timekeeping ability of the product and prevent any possible time jumps in the rare case (seen only once) of a hardware glitch on the circuit board. RECOMMENDATION: Upgrade if you would like the feature listed in #2 above. |
3.02 | 1.ÌýTo enhance SSH security, the default was changed from accepting versions 1 and 2 protocol connections to only accepting version 2 protocol connection.Ìý Version 1 is considered insecure. 2.ÌýFixed a bug wherein the unit continued to serve time for too long after loss-of-lock to synchronization signal (GPS/CDMA). RECOMMENDATION: Please upgrade. |
3.01 | 1.ÌýFixed a bug related to the AM/PM local time display. 2.ÌýAdded 0.1 meter resolution capability to the console "setgpsrefpos" script for GPS products. RECOMMENDATION: Upgrade if you use local time 12-hour mode for your display. |
3.00 | 1.ÌýAdded ability to set optional Serial Time Output format via front-panel keypad/display. 2.ÌýAdded ability to mask off certain alarms - the Antenna Fault in GPS products and the Signal Loss Fault in both GPS and CDMA products.Ìý If you are operating your time server as a Stratum II Server then you may want to mask off these alarms. 3.ÌýAdded more selections for the optional Programmable TTL Output. 4.ÌýAdded alternative Time Display that shows the time with Day-Of-Year as: DOY:HH:MM:SS. 5.ÌýFixed a bug related to unprivileged user in cntpstat/gntpstat reporting. RECOMMENDATION: Upgrade if you care about one of the items listed above. |
2.63 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.62 | 1.ÌýFixed a bug related to changing DST information via the front-panel display. 2.ÌýFixed a bug when entering positive time zone offsets via console port command "timemodeconfig". RECOMMENDATION: Upgrade if you are in a positive time zone (east of Greenwich Mean Time) or you use the Daylight Savings Time (DST) feature. |
2.61 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
2.60 | 1.ÌýMajor upgrade with updated versions of all applications, utilities and shared libraries typically installed in an embedded Linux-based system.Ìý Please click hereÌýfor IMPORTANT information. RECOMMENDATION: Please upgrade. NOTE: This software release is IPv6-capable.Ìý IPv6 is in the experimental stage but some of our customers want it now.Ìý In order to enable IPv6 operation you must perform a second upgrade operation to replace your IPV4-only kernel.Ìý If you want IPv6 operation then clickÌýhereÌýto download the IPv6-capable Linux kernel. |
2.05 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.04 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.03 | Changes include: 1.ÌýFixed a bug in NTP that continued to report Stratum 1 with TFOM=9.Ìý However, the unit correctly refused to reply to NTP client requests, so this problem was only seen in reports. 2.ÌýFixed a bug related to time displayed on the front-panel when the unit was in Local Manual time mode with DST enabled. RECOMMENDATION: No need to upgrade. |
2.02 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
2.01 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
2.00 | This release was an integration of Time Server and Time & Frequency products into the same firmware image with automatic boot time configuration of the model and receiver type. RECOMMENDATION: No need to upgrade. |
Ìý
Receiver Subsystem (GPS or CDMA) — Software Part Number 6010-0020-000
Version | Changes |
5.11 | Changes include: 1.Ìý Improved spoofing & error protection on data received from GPS. 2.Ìý Corrected bug in GPS Subsystem, where leap second does not occur properly unless the unit is locked to a GPS signal at UTC midnight.Ìý (Does not apply to CDMA-Synchronized Tempus LX.) RECOMMENDATION: GPS users please upgrade.Ìý If the Linux Subsystem in your Tempus LX is prior to version 5.00, you must also upgrade the Linux Subsystem. |
5.10 | Changes include: 1.Ìý Corrected week rollover problem caused by GPS receiver from 3rd-party vendor.Ìý Problem began at UTC midnight on Feb 14, 2016.Ìý After upgrading to v5.10, this product should not be affected by another GPS week rollover until the year 2035.Ìý For details, read thisÌýField Service Bulletin. 2.Ìý Added error checking on UTC offset parameters received from GPS receiver. RECOMMENDATION: GPS users please upgrade. |
5.09 | Corrected TFOM changing too quickly for some GPS antenna installations.Ìý TFOM would quickly change from 3 to 4 and back again, which caused unwanted SNMP trap notifications.Ìý (This behavior will continue to be appropriate for some GPS window-mount installations.) RECOMMENDATION: GPS users upgrade if you have experienced this problem. |
5.08 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
5.07 | Added new CDMA frequencies for operation in Korea and Hong Kong. RECOMMENDATION: CDMA users in Korea please upgrade. |
5.06 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
5.05 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
5.04 | 1.ÌýImproved CDMA receiver operation in noisy/multipath environments. 2.ÌýCorrected bug that wore out FLASH memory chips on GPS units operating for long periods of time without an antenna - such as during Stratum 2 operation.Ìý See thisÌýField Service Bulletin. RECOMMENDATION: GPS users please upgrade. |
5.03 | Corrected bug introduced in version 5.00 (GPS only). RECOMMENDATION: GPS users please upgrade. |
5.02 | Improved IRIG-B time code generation.Ìý RECOMMENDATION: No need to upgrade unless your unit has the IRIG-B option and the time code reader you are using is having trouble reading the IRIG.Ìý (Rare problem - seen only once.) |
5.01 | 1.ÌýMost changes not relevant to the Tempus LX. 2.ÌýAdded capability for CDMA model to operate in Sri Lanka. RECOMMENDATION: No need to upgrade. |
5.00 | 1.ÌýMost changes not relevant to the Tempus LX. 2.ÌýCorrected rare bug in GPS leap second processing. RECOMMENDATION: GPS users upgrade before next leap second occurrence. |
4.00 | 1.ÌýAdded capability for CDMA model to operate in India. 2.ÌýAdded additional format selections to the Serial Time Output Option. 3.ÌýChanged TFOM value for GPS model to be in the range of 9-3 (was 9-4).Ìý Note: TFOM is usually irrelevant for time server customers. 4.ÌýCorrected bug in the IRIGB-120/IEEE1344 output. 5.ÌýAdded CRC checking on the time information going from the Receiver Subsystem to the NTP Subsystem.Ìý This will further bulletproof the timekeeping ability of the product and prevent any possible time jumps in the rare case (seen only once) of a hardware glitch on the circuit board. RECOMMENDATION: Upgrade if you are using the optional IRIGB-120/IEEE1344 output. |
3.03 | Added NMEA0183 format to the Serial Time Output option. RECOMMENDATION: No need to upgrade. |
3.02 | Change not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
3.01 | Added software to work with new version of hardware circuit board.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
3.00 | No change.Ìý Version bumped to maintain synchronization with NTP Subsystem version. RECOMMENDATION: No need to upgrade. |
2.13 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.12 | Test routine added for factory manufacturing.Ìý Irrelevant for customer. RECOMMENDATION: No need to upgrade. |
2.11 | Added new string format selections for optional Serial Time Output. RECOMMENDATION: No need to upgrade. |
2.10 | Test routine added for factory manufacturing.Ìý Irrelevant for customer. RECOMMENDATION: No need to upgrade. |
2.09 | Changed optional time code format selection list.Ìý Irrelevant for most Tempus LX users unless you have the time code output option. RECOMMENDATION: Upgrade if you have the timecode output option. |
2.08 | Fixed a bug in the time display when the timemode was set for GPS (as opposed to UTC or Local).Ìý Generally this timemode is not used in Network Time Servers. RECOMMENDATION: No need to upgrade. |
2.07 | Changes include: 1.ÌýCorrected extremely rare bug for GPS units that occurred only in very high interference environments. 2.ÌýAdded RS-232 Serial Time output option.Ìý Irrelevant for previously shipped products. RECOMMENDATION: GPS users upgrade if your Tempus LX is having trouble staying locked. |
2.06 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.05 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.04 | Changes not relevant to the Tempus LX. RECOMMENDATION: No need to upgrade. |
2.03 | Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.02 | Improved error handling for GPS receiver. RECOMMENDATION: GPS users please upgrade. |
2.01 | Sysplex Timer option added.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
2.00 | Changes include: 1.ÌýChange in communication between Receiver Subsystem and NTP Subsystem. 2.ÌýTimecode output option added.Ìý Irrelevant for previously shipped products. RECOMMENDATION: No need to upgrade. |
Ìý